Description

  • Aircon turns off automatically in 30 minutes or so
  • Aircon vent has insufficient air flow
  • Aircon panel seems to always stay at some 23c
  • Aircon panel has no display

Solution

Aircon turns off in a short period

Set the mode to COOL, fan to HIGH and ON. Use +/- buttons to set the target temperate to a lower one e.g. 18c.

The aircon unit can be controlled via building control room downstairs. If the aircon stops unexpectedly in a short period and if this happens all the time, ask building caretaker 3113 or Hilton reception to reset the aircon remotely.

  • Hilton's frontdesk : 07 5680 8000
  • 3113 building manager : 07 5680 8980 Email owners@3113sp.com.au

Aircon vent has insufficient airflow

Explain to guests that each vent on the ceiling has an inhale as well as an exhale, i.e. half of the vent is inhale. The other half is exhale.

Open the aircon service door, remove the filter. Filter often gets too much dirt and blocks the normal air flow.

1372428916.jpg

IMPORTANT! Wash the filter later and put it back

Because all the ducts are connected and aircon unit cool air is distributed via those pipes and each vent, blocking a vent will help other vents to get more air flow.

  • Use a big piece of paper or sticker to block off the other room's vent. It helps the circulation of the air flow to get stronger for other vents.

Panel shows a fixed temperature

The panel is a thermal detector. When idle, it shows the current room temperature it detects.

When pressing '+/-' buttons, the panel shows the target temperature.

Panel is dead no cooling

With a new panel:

  • Turn off the aircon switchboard switch
  • Remove the old broken panel
  • Replace with a new panel
  • Turn on the aircon switch

DO NOT throw away the broken panel. It may be repairable.

Pepper's Soul LCD AC panel unresponsive

Will need a panel replacement. Contact Michel Nugent- Coolmaster PH: +61 455 733 053 E: Mnugent@coolmaster.com.au

Soul AC can also be reset using the main control panel. Please contact Micheal Applebee- Pepper's Building Manager PH: +61 407 482 123 E: micheal.applebee@peppers.com.au

Hilton AC Techs

If it is something we cannot repair, contact Johnson Control instead to schedule a repair.

Johnson Controls

24hr Service Line

1800 659 378

Contacts

Title Name Phone Email Notes
Service Team Leader Brendan Pedersen 0403 452 380 brendan.pedersen@jci.com 4/6 John Duncan Court Varsity Lakes, QLD, 4227
Service Coordinator Libby Wedmaier 07 3630 3035 libby.wedmaier@jci.com 4/121 Newmarket Road Windsor, QLD, 4030
OTC Administrator Lucy Burnett 07 3630 3206 lucy.burnett@jci.com 4/121 Newmarket Road Windsor, QLD, 4030
Service Delivery Manager Jaala Howell-Unmeopa 07 3630 3050
0456 633 715
jaala.howellunmeopa-ext@jci.com

Circle on Cavill Fujitsu Error codes

Error code EE:EE displayed instead of clock and unit will stop.

  1. If unit is ON then press Start/Stop button to turn it off.
  2. Press Set Time (down) and Set Temp/Day (down) buttons together for more than three seconds to start self diagnostic display.
  3. Press the buttons in (2) again to end check mode.

Error codes:

  • E:00 Communication error (indoor unit <-> remote controller)
  • E:01 Communication error (indoor unit <-> outdoor unit)
  • E:02 Room temperature sensor open
  • E:03 Room temperature sensor short circuited
  • E:04 Indoor heat exchanger temperature sensor open
  • E:05 Indoor heat exchanger temperature sensor short circuited
  • E:06 Outdoor heat exchanger temperature sensor open
  • E:07 Outdoor heat exchanger temperature sensor short circuited
  • E:08 Power source connection error
  • E:09 Float switch operated
  • E:0A Outdoor temperature sensor open
  • E:0b Outdoor temperature sensor short circuited
  • E:0C Discharge pipe temperature sensor open
  • E:0d Discharge pipe temperature sensor short circuited
  • E:0E Outdoor high pressure abnormal
  • E:0F Discharge pipe temperature abnormal
  • E:11 Model abnormal
  • E:12 Indoor fan abnormal
  • E:13 Outdoor signal abnormal
  • E:14 Outdoor EPROM abnormal